T80 Universal Transmitter
Measure pH, ORP, Specific Ion,
Dissolved Oxygen,
Turbidity,
Conductivity or Resistivity with
S80 Intelligent Sensors ...


* Single or dual
channel, measures
pH, ORP, DO,
specific Ion,
turbidity,
conductivity or resistivity
* Easy to navigate, configure, read
graphical and
numerical
information
* Use with digital intelligent sensors
that are factory calibrated sensors
and store data

* 4-20 mA output
with MODBUS RTU
and alarm relays : flexible
configurations
for all applications
* HART® communication

C22 Controller
Measure pH, ORP, Specific Ion, Dissolved Oxygen,
Turbidity, Chlorine,
Conductivity and Resistivity with
S10, S17, TR6 or various Chlorine Sensors ...


* Choice of multiple measurement
parameters
* Multi-Channel Capability
* SENTINEL Diagnostics

* Auto Buffer Calibration
* Pipe, Wall,
Handrail, or Panel
Installation choices

T23 Transmitter
Measure pH, ORP, Specific Ion,
Dissolved Oxygen,
Conduc2vity or Resis2vity with
S10, S17 Sensors ...


* Choice of multiple measurement
parameters
* Two Channel
Capability
* SENTINEL
Diagnostics

* Auto Buffer
Calibration
* Pipe, Wall,
Handrail, or Panel
Installation choices

T28 Transmitter
Microprocessor-based two-wire transmitter
provides ergonomic
simplicity housed
in a powerfully
designed package !...


* A choice of
measurement
parameters include pH,
ORP, specific Ion,
Dissolved Oxygen,
Conductivity or
Resistivity
* This is FM and CSA
approved for i
ntrinsically safe and
explosion proof applications. To be
installed into class I,
II, and III,
Division I Groups A through G hazardous
environments.
* Provides isolated
4-20 mA current
signals to a receiver, controller, or
recorder for
evaluation or control purposes.

S80 Intelligent Sensors
Measure pH, ORP, Specific Ion, Dissolved Oxygen, Turbidity,
Conductivity or Resistivity with
T80 Universal Transmitter ...


* Intelligent sensor design with digital
communication
* Multiple individual
measurement parameters
* Readily available application specific electrode cartridges
* Long life replaceable electrode cartridges
* Submersible and retractable sensors
* Industrial housing materials for compatibility with process fluid

S10 & S17 Sensors
Measure pH, ORP, Specific Ion,
Dissolved Oxygen,
Conductivity or Resistivity ...


* Multiple individual
measurement parameters
* Readily available application specific electrode cartridges
* Long life replaceable electrode cartridges
* Various process fitting with adjustable insertion lengths
* Industrial housing materials for compatibility with process fluid

CSX2 Conductivity Sensors
Designed for high pressure, high temperature conductivity
measurements ...


* High temperature, 200°C and high pressure, 250 psig sensor
* Redundant,
maximum reliability
* Standard pipe
fitting, no special adapters needed
* Convenient access
to wiring
* Chemically
resistant with high
heat deflection temperature
* Rugged 316
stainless steel construction

FC80 Free Chlorine
Analyzer

Designed to monitor free chlorine in drinking water,
rinse water, cooling
water or other fresh water ...


* Complete system ,
easy installation,
ready to use
* Automatic pH compensation
* Automatic flow control
* Compliant with EPA method 334.0
* No expensive reagents
* Eliminates pressure regulators and rotameters
* Dual measurements, single parameter or
dual parameter
displays, MODBUS
RTU, spray cleaner (optional for fouling application)

TC80 Total Chlorine
Analyzer

Designed to monitor total chlorine in drinking water,
rinse water, cooling
water or other fresh water ...


* Complete system ,
easy installation,
ready to use
* Automatic pH compensation
* Automatic flow control
* Compliant with EPA method 334.0
* No expensive reagents
* Eliminates pressure regulators and rotameters
* Dual measurements,
(2) 4-20 mA and
(3) alarm relays, 24vdc or 110/220 vac power, auto clean option

DC80 De- Chlorination
Analyzer

Uses the "zero shifted" strategy
to make the measurement...


*Chlorine metered into flow cell substracted from measurement
* Zero shift method, 0.00 ppm to 20.00 ppm
* Automatic pH compensation
* Automatic flow control
* No expensive reagents
* Eliminates pressure regulators and rotameters
* Dual measurements,
(2) 4-20 mA and
(3) alarm relays, 24vdc or 110/220 vac power, auto
clean option

DCA-23 Seawater
Dechlorination
Analyzer

Designed to monitor the chlorination
and dechlorination of seawater ...


* Dual input potentiometric design
* 0.00 to 2.00 ppm chlorine range
* MDL of 0.014 ppm
* No add chemicals
* No flow sensitivity
* Measures TRO
* Optimal seawater range
* Minimum detection limit
* Easy installation, connect power, feed and drain lines

CD80 Chlorine
Dioxide
Analyzer

Designed to
monitor free
chlorine in
drinking water,
rinse water,
cooling water
or other fresh
water ...


* Complete system ,
easy installation,
ready to use
* Amperometric design
* Automatic flow control
* Compliant with EPA method 334.0
* No expensive reagents
* Eliminates pressure regulators and rotameters
* Dual measurements, single parameter or
dual parameter
displays, MODBUS
RTU, spray cleaner (optional for fouling application)

HP80 Hydrogen
Peroxide
Analyzer

Available in several ranges to suit its various application ...

* Complete system ,
easy installation,
ready to use
* 0-200 ppm, 0-20.0%
* Automatic flow control
* Multiple H2O2 ranges
* Eliminates pressure regulators and rotameters
* Dual measurements, single parameter or
dual parameter
displays, MODBUS
RTU, spray cleaner (optional for fouling application)

OZ80 Ozone
Analyzer

Available in several ranges to suit its various application ...

* Complete system ,
easy installation,
ready to use
* 0-2.00 ppm, 0-20.0 ppm
* Automatic flow control
* Multiple O3 ranges
* Eliminates pressure regulators and rotameters
* Dual measurements, single parameter or
dual parameter
displays, MODBUS
RTU, spray cleaner (optional for fouling application)

PA80 Peracetic
Acid Analyzer

Complete system ,
easy installation,
ready to use ..
.

* Multiple PAA ranges
* 0-20, 0-200,
0-2,000 ppm
* Automatic flow control
* Eliminates pressure regulators and rotameters
* Dual measurements, single parameter or
dual parameter
displays, MODBUS
RTU, spray cleaner (optional for fouling application)

DO90 Trace
DO2 Sensor
Analyzer

Designed for continuous measurement of trace levels of dissolved oxygen in aqueous systems ...

* Large measurement ranges
* 0.001 to 20.00 mg/l chlorine range
* Long term stability
* Lead silver galvanic cell
* Diff < 1% per month
* No membrane or fill solutions to mess with
* Air calibration or zero calibration
* Noise free signal, calibration store in the sensor
* Minimal maintenance
* Replaceable electrode

TRITON®
DO82
Dissolved
Oxygen Sensor

Uses fluorescence
quenching to
determine the
oxygen concentra1on
in water ...


* Optical dissolved oxygen sensor
* Intelligent sensor
with stored calibration data
* Ultra long life membrane cap
* Membrane cap is easily replaceable
* Universal design with waterproof fixed or detachable cable
* 4-20 mA with MODBUS RTU or
HART®on the T80 transmitter, single or dual channel models

HYDRA®
Ammonium
Analyzer

Measures the concentration
of dissolved ammonium as nitrogen
(NH4+-N) in water. ...


* Fast and accurate ammonium measurement NH4+ or NH4+-N
* Fully compensated for pH, K+ interferrences & temperature
* Removable electrode guard for easy maintenance
* Clean sensor in situ with pressurized water or air
* Ammonium ISE electrode
* K+, pH and temp.electrodes
* Integral spray head cleaner

HYDRA®
Nitrate
Analyzer

Measures the concentration
of dissolved nitrate as nitrogen
(NO3--N) in water ...


* Fast and accurate nitrate measurement NO3- or NO3--N
* Fully compensated for Cl- interferrences & temperature
* Removable electrode guard for easy maintenance
* Clean sensor in situ
with pressurized water or air
* Nitrate ISE electrode
* Cl and temp.
electrodes
* Integral spray
head cleaner

61 Boiler Blowdown
System

Provides a reliable solution for the
continuous control
of the surface blowdown rate for commercial and industrial boilers ...


* Improves the accuracy and the longevity of the conductivity measurement
* Local display, 4-20 mA output, alarm relays, XY graphical plot
* Sample conditioner reduces temperature prior to the conductivity measurement

2122 Cooling Tower Control
System

An integrated system designed
to controls acid feed, blowdown and inhibitor feed in cooling processes ...


* Conductivity controls the blow down and the pH controls the acid or base feed
*Dual input design, pH and conductivity sensors
* Reduces cost and waste by inhibiting excess chemical feed
* Control logic and failsafe interlocks
* Local display, 4-20 mA output, alarm relays, XY graphical plot, PID, logic functions
* Bioxide feed timer

CA-6 Online Analyzers
A family of on-line sequential sampling analyzers that use colorimetric technology to perform an analysis ...

* Easy installation
* User friendly menu structure
* Touchscreen interface
* Easy process configuration
* Epoxy powder coated
* Two seperate compartments (electronics and hydraulics)

CA-6 UV Analyzers
A family of on-line sampling analyzers that use UV absorption to perform an analysis ...

* Easy to start up and use , simply connect the sample, waste and cleaning solution/
reagents lines

SMS-22 Sulfide Ion Measuring System
An all in one analyzer for the continuous measurement of sulfide ions in
aqueous media ...


* Compact all in one measurement system
* ISE based sulfide ion measurement
* pH adjusted and compensated measurement
* Sample neutralized after measurement